Industries

The operating system for regulated service contractors.

Inspections, deficiencies, quotes, schedules and billing for work that has to be done to a standard and proven afterwards. Fire protection and backflow first, now emergency power, kitchen exhaust cleaning and elevators, and service work for HVAC shops.

Available today

6 industry packs, one way of working.

Fire protection

Deepest

NFPA 25 · 13 · 10 · 17A · 72 · 101 · 2001 · 12 · 17 · 80

Every fire protection system in the building, on one phone.

For fire sprinkler, fire alarm, extinguisher, suppression and life safety contractors

  • NFPA 25 forms for wet and dry pipe sprinklers, fire pumps, standpipes, private mains, tanks and valves, and the NFPA 13 acceptance hydrostatic test
  • One row per extinguisher, fire alarm device, emergency light, fire door or agent cylinder
  • Kitchen hood suppression systems to NFPA 17A, special hazards to NFPA 2001, 12 and 17
  • Device tags with a QR code, deficiencies kept against each device

Backflow

Deepest

AWWA · local water authority

Backflow tests with the tester and the test kit on every report.

For backflow testers and the plumbing and fire companies that employ them

  • The assembly's make, model, size and serial, kept as a device at the building
  • Reduced pressure and double check readings in psid, and the assembly's result and status
  • The tester's certification number and the test kit with its certification date, filled in from the tester's own kit

Emergency power

New

NFPA 110

Generators and transfer switches, tested and logged.

For generator service companies and electrical contractors who maintain standby power

  • One row per generator: make, model, serial and kW, kept as a device at the building
  • Run hours on arrival and departure, exercise under load with the load and run time
  • Transfer switch test with the time to transfer, and load bank steps when one is run
  • Starting batteries and charger, fuel level and condition, coolant, oil and leaks, fuel storage
  • Defects found, who they were reported to, and the unit left in automatic

Kitchen exhaust cleaning

New

NFPA 96

Kitchen exhaust cleaning, with before and after to show for it.

For kitchen exhaust (hood) cleaning companies

  • One row per exhaust system: hood, filters, duct route and fan
  • Grease depth before and after, access panels used and resealed
  • Hood, duct and fan cleaned to bare metal, and every area not cleaned with the reason
  • Before and after photos, the service label, and the customer's sign-off on site
  • The cleaning interval agreed with the customer and the next cleaning date

Elevators

New

ASME A17.1 · A17.2 · A17.3

Every car, escalator and lift, with its permit and its tests.

For elevator contractors and the mechanics and inspectors who maintain and test elevators, escalators and wheelchair lifts

  • One row per unit: traction, hydraulic, MRL, escalator or lift, with its state ID, operating permit and expiry, capacity and floors served
  • Machine room, controller, hoistway, pit, car top, doors and restrictors, car interior, leveling, governor, buffers and hydraulic fluid
  • Emergency communication and car lighting tests, and firefighters' emergency operation (Phase I recall and Phase II)
  • A periodic test record for Category 1, 3 and 5 tests: readings, who witnessed them, the AHJ inspector and the certificate issued
  • The mechanic's license number and QEI certificate number on every report

Commercial & residential HVAC

New

Service work · EPA Section 608 refrigerant records

Heating and cooling service, from the first call to the paid invoice.

For commercial and residential HVAC shops, from one truck to a fleet

  • Preventive maintenance with one row per unit: make, model, serial, size and refrigerant, filters, belts, coils, drains and electrical
  • Capacitor and amp readings, supply and return temperatures with the temperature split, static pressure and thermostat
  • CO readings and a heat exchanger check on gas heat
  • Service call reports: the complaint, what was found, the work done, parts used and the customer's signature
  • Refrigerant records (EPA Section 608): the technician's certification, pounds and ounces added and recovered, recovery cylinder and leak checks

Whatever the industry

Every pack gets the whole of Serdock.

Forms on a phone with photos and signatures, devices kept at each building, deficiencies turned into quotes, schedules that roll forward, invoices through QuickBooks, the customer portal and your own website.

Turn on what you do

Each industry is a pack in Settings, with its forms under it. An HVAC shop or a generator company never sees a sprinkler form.

Your frequencies, not ours

Every site's schedule carries the interval your company sets with the owner and the authority having jurisdiction.

Records, not claims

Reports record what was done and found, cite the standard each field comes from, and never declare a building compliant.

Coming later

On the list, not in Serdock yet.

These packs are planned. There are no built-in forms for them today; if you do this work, tell us what your reports need.

  • Coming later

    Boilers & pressure vessels

  • Coming later

    Medical gas

  • Coming later

    Environmental sampling

Tell us about your work

Questions

Which industries does Serdock support today?
Six: fire protection, backflow, emergency power, kitchen exhaust cleaning, elevators, commercial & residential HVAC. Fire protection and backflow have the most forms; emergency power, kitchen exhaust cleaning, elevators and HVAC are new.
HVAC isn't regulated like fire protection. Why is it here?
Because small heating and cooling shops need the same things: a website that gets found, quotes, jobs, scheduling, maintenance plans that come round again, invoices and a customer portal. The HVAC pack is plain service work (maintenance and service call reports), with one regulated record: refrigerant added and recovered, for EPA Section 608.
What about boilers and pressure vessels, medical gas or environmental sampling?
They are on our list but not in Serdock yet, and there are no forms for them today. Until then, the form builder makes a company form of your own for any work Serdock has no built-in form for.
Does Serdock decide how often a generator is exercised, a hood is cleaned or an elevator is tested?
No. Your company sets each site's frequency on its schedule, with the owner and the authority having jurisdiction. Forms cite the standard a field comes from; they don't set intervals or declare anything compliant.
Is kitchen exhaust cleaning the same as the kitchen hood suppression inspection?
No. Cleaning grease from the hood, duct and fan is one pack with its own report. Inspecting the wet chemical suppression system is part of the fire protection pack. A company can run either or both.
What happens to our reports if we turn a pack off?
Nothing is deleted or hidden. Reports, devices, deficiencies and schedules already saved stay where they are; the pack's forms just can't be started or scheduled again until you turn it back on.

See it with your own work in mind.

A 30-minute walkthrough, on the inspections and jobs you actually do.